Procedure for Obtaining Swimming
Pool Permits
Printable
version of Procedures
RESIDENTIAL:
Application must be made for above ground and in-ground swimming pools and spas. Plan Review fee
due at submittal $25.00.
A compliance statement must be on plans stating design is
according to the 2004
Florida Building Code with the 2006 amendments and
the ANSI/NSPI - 5 standard for the design, construction, and workmanship of swimming pools.
All suction inlets must be identified and noted with inlet covers that meet ANSI/ASME A112.19.8M
Standards.
Each application for a swimming pool permit will have to detail the barrier requirements to be included as
part of the pool construction and be installed at the time of final inspection. Pool safety features: barrier,
alarms, self-closing latching doors, pool cover.
Supply property STRAP NUMBER (found on upper left corner of property tax statement), property owners
name, phone number, address of job, directions to job site and pool value.
When the plans are approved, you will be notified to pick up the permit. (Either by phone,
fax or by mail)
Every above ground swimming pool, in-ground pool, hot tub, spa or similar facility shall be enclosed by a
fence, wall, screen enclosure or other structure, not less than four (4) feet in height, constructed or
installed so as to prevent unauthorized access to the pool. This requires a separate enclosure permit. See
ENCLOSURES.
IN-GROUND POOLS:
Submit three (3) copies of the following:
a. Plot plan - must include: lot size, setbacks to front, sides and rear property lines from existing
structures and proposed pool area, size of pool, dimensions of deck and location of steps, ladder
and pool equipment.
b. Cross section and plan view of pool showing steps, ladder, deck details and footing details.
ABOVE GROUND POOLS: (24" and above require a pool permit)
Submit three (3) copies of the following:
a. Plot plan - must include: lot size, setback to front, sides and rear of property lines from existing
structures and proposed pool area, size of pool, dimensions of deck and location of steps, ladder
and pool equipment.
b. Manufacturer's specifications on how to erect the pool and specifications on self-locking ladders.
c. If a deck is going to be erected around the pool construction details are required. NOTE: If deck
is 30 inches or more above the ground level, these plans must be sealed by a Florida
registered architect or engineer with compliance statement for the 2004 Florida Building
Code with the 2006 amendments.
FEES DUE: (due at time of issuance of permit)
In-ground Pool - $90.00
Electrical Permit - $40.00
In-ground Spa - $35.00
Above ground Pool - $35.00 ***An electric permit is required***
INSPECTIONS: Please use automated system 239-533-8997
IN-GROUND POOLS:
1. Pool Retaining Wall/Pile caps (101 inspection on automated system).
2. Pool Steel - structural, including main drain (108 inspection on automated system).
3. Electrical Bonding at time of Pool Steel ( 304 inspection on automated system).
4. Pool Deck - structural (109 inspection on automated system).
5. Electrical Bonding of Pool Deck (304 inspection on automated system).
6. Pool final including the electric (119 inspection on automated system). This inspection should only
be called for after the permanent enclosure is in place and an enclosure permit posted.
For Commercial Pools in addition to 1-6 above the following are required: Development Services
inspection which is requested through letter of Substantial Compliance submitted to permitting counter.
Approval from Lee County Health Department.
ABOVE GROUND POOLS:
1. Pool and deck (if applicable) erected, Electrical and Bonding Inspection (Pool Final 119)
ENCLOSURE/FENCE/RAILING/WALL
This requires a separate permit which must be posted and the permanent enclosure erected before final
inspection of the pool
- Submit three (3) copies of the following:
- Plot plan showing lot size, setbacks to front, sides and rear property lines, any easements on the
property, existing buildings, pool area, and dimensions regarding enclosure area.
If
COMMERCIAL, we must have three (3) sets of approved Development Order.
- Aluminum enclosure - architect or engineered sealed construction drawing. If plans are
mastered with Lee County, we will need to know the master number.
- Fence/Rail - detail showing construction, spacing of posts, self locking gates and height.
- Wall - architect or engineered sealed construction drawings.
- Supply property strap number (found on upper left corner of property tax statement), address and
directions to job site.
- Submittal fee for plan review is $25.00
- Fees due at time of permit pickup:
Aluminum enclosure $45.00
Fence $25.00
Wall $ .50 plf $50.00 minimum
- Required inspections:
Wall Foundation, column, final
Enclosure/Fence/Railing - Final (after erected)
COMMERCIAL:
Prior to application to the Division of Codes and Building Services:
a. The Lee County Health Department requires that the plans for a commercial swimming pool be
completed by an engineer and submitted to them for approval.
b. Development Review is required - Show pool house, pool and four (4) feet minimum fence, rail,
wall or enclosure.
Submit three (3) sets of the following:
a. Health Department stamped approved plans and provisions
b. Site Plan indicating set backs . (A separate permit is required for enclosure, fence wall or
railing) Development Order number which indicates the approved D.O.
Plan Review fee is $50.00
NOTE: All construction must be
according to the 2004 Florida Building Code
with the 2006 amendments, Wood fences, chain link fences with
slats and walls are required to be
according to the 2004 Florida Building Code
with the 2006 amendments and require engineer sealed construction
drawings. Zoning approval is required on commercial pool replacements.
return to the top |