Single Family/Duplex
- Completed Application (get the application
here)
- Property owner's name
- STRAP Number (17 digit number found on tax bill, available
from the Lee County Property
Appraisers Website or at 239-533-6150)
- Site address
- Directions to job from downtown Fort Myers
- Contractor information (Name, License Number, Address, Phone
& Fax Number
- Electrical amps, Roof type, HVAC SEER rating KW’s
& tonage
- Plot/Site Plan
Three (3) copies of a plot/site plan drawn to scale (1/8" = 1'
minimum). The scale and north arrow must be indicated. The following
items must be on your plot/site plan:
A. All four lot corners, lot lines and dimensions; B. Location
and name of streets or drives bordering the lot; C. If there is a
water body within 25 feet of your project, indicate the mean high
tide line or the edge of water and label the type of water body (for
example: lake, creek, canal, river, Gulf). D. The size of the
existing and proposed building(s); the location of driveways; and
the location of all easements on the lot. E. Setbacks of the
buildings (and any proposed additions thereto) from the four lot
lines and other existing structures. Setbacks must be taken from the
closest point of the building to the closest point of the property
line. F. The plans must show the roof line as well as the
foundation. Roof lines may not encroach into or over
easements.
3. COASTAL ZONE
A. If the property is located within a coastal zone area, a
certified sealed survey indicating both Coastal Construction Zone
lines, the Flood Zone requirement for the zone, and existing
elevation of grade must be submitted with the application. B. If
the property is located on a BARRIER ISLAND, i.e. FT MYERS BEACH,
CAPTIVA, UPPER CAPTIVA, BOCA GRANDE, BONITA GULF FRONT property,
etc., the construction drawings must be sealed by a registered
Florida architect or engineer and the certified survey must address
the COASTAL CONSTRUCTION ZONE in addition to flood zone. C. A
certified elevation certificate will be required indicating the NGVD
elevation prior to tie beam inspection on CBS structures or framing
inspection on wood structures.
NOTE: The form is to be completed by your surveyor and returned
to the Inspection Department with the Building Permit number on
it.
4. MASTERED BUILDINGS: If you are planning on purchasing a
garage, gazebo, pole barn, shed or utility building from a local
distributor, please check with them to see what brands and model
numbers are mastered with Lee County Development Services. If the
particular model that you want to buy is not mastered with Lee
County Development Services, the plans will have to be sealed. (See
#5 Construction Details)
5. CONSTRUCTION DETAIL (BLUEPRINTS)
Plans that are prepared by a Florida registered architect or
engineer shall be prepared in compliance with required wind loads
and must contain a statement on the plan that the building/structure
has been designed according to the 2004 Florida Building Code with
the 2006 amendments. The
following information related to wind loads shall be shown on the
construction drawings:
- Basic wind speed, mph, (m/s).
- Wind importance factor (l) and building category.
- Wind exposure - if more than one wind exposure is used, the
wind exposure and applicable wind direction shall be indicated.
- The applicable internal pressure coefficient.
- Components and Cladding. The design wind pressures in terms of
psf (kN/m2), to be used for the design of exterior component and
cladding materials not specifically designed by the registered
design professional.
If the construction is located in a coastal area specific to the
limitations under The Lee County Land Development Code, Chapter 14,
Article II, Division 2, Sea Turtles; also Chapter 6, Article III
Coastal Construction Code, and Article IV Flood Hazard Reduction,
the architect or engineer shall provide a statement of compliance
with those applicable code sections
Plans should be submitted on standardized sheets drawn to scale
(1/8" or 3/32" = 1' is acceptable). Three (3) sets of construction
drawings must be submitted. The plans must bear the following
specific information:
- Elevation for front, rear, right and left sides.
- Foundation plans.
- Floor plans. If an addition or enclosure,
floor plans must identify rooms adjacent to the addition/enclosure
as well as means of ingress/egress.
- Lateral breakdown (typical
wall section from roofing through to foundation and NGVD
Elevation.
- Duplex must have a tenant separation wall of UL
Design or equal.
- Location of electric and plumbing.
- Conventional roof framing layout. If trusses, include engineered
truss layout from truss manufacturer.
- If living area, three
sets of 2004 energy calculations (revised) will be required.
- Manufacturers cut sheets for impact resistant windows, doors
& garage doors, and shutters, including installation & design
standards, any testing or compliance information available. IF
MASTERED, PROVIDE SHEETS DETAILING THE MASTER #, MANUFACTURER
NAME AND SERIES # OF EACH WINDOW, EXTERIOR DOOR, GARAGE DOORS
AND SHUTTERS.
- If construction requires
sprinklers, plans must show compliance with State of Florida
Administrative Code 61G15-32
6. PUBLIC WATER/SEWER (SFR & DUPLEX ONLY)
If construction is located on private or public water and sewer,
a letter must be submitted from the appropriate utility company
verifying availability to the site at the time of submittal of
application.
7. SEPTIC (SFR, DUPLEX, ADDITIONS, SANITARY
FACILITIES)
If construction is located on SEPTIC SYSTEM, applicant must apply
for his Septic Permit at the Health Department prior to the
submittal of the building permit. A copy of the paid receipt is
required at submittal of building permit. (Applications are
available at Development Services) If Septic is existing, you will
need a letter from the Health Dept. stating it will be sufficient
for size of dwelling at the time of submittal. (2295
Victoria Avenue 239-690-2100)
8. WELL (SFR & DUPLEX ONLY)
If the property requires a well for potable water, a signed
Well Affidavit must be submitted at the time of application for
a building permit. The Well permit must be obtained and inspection
finaled before the Certificate of Occupancy will be issued. If the
well is existing, a letter stating compliance from Natural Resources
will be required at the time of application. (239-533-8114)
9. ENERGY CALCULATIONS (SFR, DUPLEX AND/OR ALL LIVING AREA
ADDITIONS)
Three (3) copies of the 2004 energy calculations and one (1)
cover sheet (copy of 1st page of energy calcs) must be submitted
with your application.
10. OWNER-BUILDER DECLARATION OF SELF USE (on back of
application)
An owner-builder must sign a
declaration of self-use. He/She must
be able to do all the work himself or hire licensed contractors.
11. NOTICE OF COMMENCEMENT (if construction value is $2500 or
more)
A
Notice of Commencement must be recorded with the Lee County
Clerk of Courts prior to issuance of the building permit. A copy of
the recorded Notice of Commencement must be supplied at the time of
pick-up of your building permit. (Notice of Commencement phone #
239-533-5007)
12. BUILDING ADDENDUM (if owner is not the
builder).
Addendum on back of application must be completed.
13.
IMPACT LETTER (SFR & Duplex Only) obtained
from Development Services must be completed.
14. DRAINAGE. If
the final grade on the lot exceeds 18 inches above the crown of the
road or any adjacent developed lot, and is not in a subdivision
subject to a current (active) Development Order, it will need to
comply with the LDC Section 34-3104. A COPY OF THE SITE FILL GRADING
PLAN MUST ACCOMPANY THE PERMIT APPLICATION.
15. DRIVEWAYS, LANDSCAPING &
IRRIGATION (DUPLEX) Permits for a duplex (two family or
single family attached), and not in a subdivision subject to a
current (active) Development Order, will be required to comply with
the LDC Section 34-3107 and 34-3108, paved driveways, landscapes and
irrigation.
return